รายละเอียดสินค้า |
Specifications
Hardware Specifications
Port Specifications
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Fixed service port
|
24 x 100/1000/2.5G/5GBASE-T ports, supporting PoE/PoE+/PoE++
4 x 10GE/25GE SFP28 ports
|
12 x 100/1000/2.5G/5G/10GBASE-T ports, supporting PoE/PoE+/PoE++
4 x 10GE/25GE SFP28 ports
|
24 x 100/1000/2.5G/5G/10GBASE-T ports, supporting PoE/PoE+/PoE++
4 x 1GE/10GE SFP+ ports
4 x 10GE/25GE SFP28 ports
|
48 x 100/1000/2.5G/5GBASE-T ports
● Ports 1 to 48 support PoE/PoE+
● Ports 1 to 24 support PoE++
4 x 10GE/25GE SFP28 ports
2 x 40GE QSFP+ ports
|
Module slot
|
/
|
/
|
2 x power module slots
3 x fan module slots
|
Power module
|
/
|
/
|
RG-PA600I-P-F
RG-PA1000I-P-F
|
Fan module
|
/
|
/
|
M2SFAN I-F (pre-installed 3)
|
Fixed management port
|
1 x RJ45 console port
1 x RJ45 MGMT port
|
USB
|
1 x USB port
|
System Specifications
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Packet forwarding rate
|
327 Mpps
|
327 Mpps
|
565 Mpps
|
625 Mpps
|
Switching capacity
|
440 Gbps
|
440 Gbps
|
760 Gbps
|
840 Gbps
|
CPU
|
Dual-core CPU, with a clock speed up to 1.25 GHz
|
BootROM
|
16 MB (storing boot software for 1+1 boot redundancy)
|
Flash memory
|
1 GB (storing boot software for 1+1 boot redundancy)
|
Memory
|
1 GB
|
1 GB
|
1 GB
|
2 GB
|
Switch buffer
|
4 MB
|
MAC address table size
|
32,768
|
ARP table size
|
16,000
|
Number of IPv4 unicast routes
|
16,000
|
Number of IPv4 multicast routes
|
4,000
|
Number of IPv6 unicast routes
|
16,000
|
Number of IPv6 multicast routes
|
2,000
|
Number of ACEs
|
Ingress: 2,500
Egress:1,000
|
Number of VSU members
|
2
|
Dimensions and Weight
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Unit dimensions (W x D x H)
|
442 mm x 220 mm x 43.6 mm (17.40 in. x 8.66 in. x 1.72 in.)
|
Shipping dimensions (W x D x H)
|
568 mm x 366 mm x 226 mm
(22.36 in. x 14.41 in. x 8.90 in.)
|
563 mm x 563 mm x 210mm
(22.17 in. x 22.17 in. x 8.27 in.)
|
Rack height
|
1 RU
|
Unit weight
|
3.65 kg (8.82 lbs)
|
6.11 kg (13.47 lbs)
|
Shipping weight
|
5.37 kg (11.84 lbs)
|
8.12 kg (17.90 lbs)
|
8.42 kg (18.56 lbs)
|
Power Supply and Consumption
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
Power supply
|
1 x fixed power supply
|
1 x fixed power supply
|
Power input
|
AC input
● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz
● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz
● Maximum input current: 6 A
|
Maximum output power
|
Built-in power supply: 460 W
|
Maximum power consumption
|
90 W (without PoE)
460 W (full PoE load)
|
PoE port
|
Ports 1 to 24 support PoE/PoE+ and HPoE power supply (IEEE 802.3af/at and 802.3bt).
|
Ports 1 to 12 support PoE/PoE+ and HPoE power supply (IEEE 802.3af/at and 802.3bt).
|
PoE power cable pairs
|
Four pairs (1-2, 3-6, 4-5, and 7-8 pairs)
|
PoE output power
|
Each PoE port provides up to 90 W of power
The maximum power is 370 W
|
Power Supply and Consumption
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Power supply
|
2 x pluggable power modules
|
Power module redundancy
|
1+1 power redundancy
|
Power module hot swapping
|
Supported
|
Power input
|
RG-PA600I-P-F (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz
● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz
● Maximum input current: 8 A
RG-PA1000I-P-F (AC input 1):
● Rated input voltage: 100 V AC to 130 V AC, 50 Hz to 60 Hz
● Maximum input voltage: 90 V AC to 143 V AC, 47 Hz to 63 Hz
● Maximum input current: 12 A
RG-PA1000I-P-F (AC input 2):
● Rated input voltage: 200 V AC to 240 V AC, 50 Hz to 60 Hz
● Maximum input voltage: 180 V AC to 264 V AC, 47 Hz to 63 Hz
● Maximum input current: 8 A
|
Maximum output power
|
RG-PA600I-P-F: 600 W
RG-PA1000I-P-F:
● 100 V AC to 130 V AC: 930 W
● 200 V AC to 240 V AC: 1000 W
|
Maximum power consumption
|
150 W (without PoE)
1,800 W (full PoE load)
|
200 W (without PoE)
1,800 W (full PoE load)
|
PoE port
|
Ports 1 to 24 support PoE/PoE+ and HPoE power supply (IEEE 802.3af/at and 802.3bt).
|
Ports 1 to 24 support HPoE power supply (IEEE 802.3bt)
Ports 1 to 48 support PoE/PoE+ power supply (IEEE 802.3af/at)
|
PoE power cable pairs
|
Four pairs (1-2, 3-6, 4-5, and 7-8 pairs)
|
PoE output power
|
Each PoE port provides up to 90 W of power
● 1 x RG-PA600I-P-F:450 W
● 1 x RG-PA1000I-P-F: 760 W (100 V AC to 130 V AC)
● 1 x RG-PA1000I-P-F: 850 W (200 V AC to 240 V AC)
● 2 x RG-PA600I-P-F:930 W
● 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1200 W (100 V AC to 130 V AC)
● 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1290 W (200 V AC to 240 V AC)
● 2 x RG-PA1000I-P-F: 1470 W (100 V AC to 130 V AC)
● 2 x RG-PA1000I-P-F: 1650 W (200 V AC to 240 V AC)
|
Each port of ports 1 to 24 provides up to 90 W of power
Each port of ports 25 to 48 provides up to 30 W of power
● 1 x RG-PA600I-P-F:400 W
● 1 x RG-PA1000I-P-F: 710 W (100 V AC to 130 V AC)
● 1 x RG-PA1000I-P-F: 800 W (200 V AC to 240 V AC)
● 2 x RG-PA600I-P-F:880 W
● 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1150 W (100 V AC to 130 V AC)
● 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1240 W (200 V AC to 240 V AC)
● 2 x RG-PA1000I-P-F: 1420 W (100 V AC to 130 V AC)
● 2 x RG-PA1000I-P-F: 1600 W (200 V AC to 240 V AC)
|
Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device.
Environment and Reliability
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Temperature
|
Operating temperature: 0°C to 45°C (32°F to 113°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
|
Humidity
|
Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing)
|
Altitude
|
Operating altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.)
Storage altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.)
|
Mean time between failure (MTBF)
|
194,297 hours (about 22 years)
|
194,297 hours (about 22 years)
|
194,297 hours (about 22 years)
|
237,221 hours (about 27 years)
|
Fan
|
2 x fixed fan modules
|
3 x pluggable fan modules
|
Fan redundancy
|
Not supported
|
2+1 redundancy
|
Fan module hot swapping
|
/
|
Supported
|
Heat dissipation
|
Fan cooling, front-to-right and left-to-right airflow
|
Fan cooling, front-to-rear and left-to-rear airflow
|
Acoustic noise
|
27°C (80.6°F): 40 dB
45°C (113°F): 78 dB
|
27°C (80.6°F): 40 dB
45°C (113°F): 78 dB
|
27°C (80.6°F): 60 dB
45°C (113°F): 78 dB
|
27°C (80.6°F): 60 dB
45°C (113°F): 78 dB
|
Power module hot swapping
|
/
|
/
|
Supported
|
Supported
|
Fan module hot swapping
|
/
|
/
|
Supported
|
Supported
|
USB hot swapping
|
Supported
|
Supported
|
Supported
|
Supported
|
Cable hot swapping
|
Supported
|
Supported
|
Supported
|
Supported
|
Power supply monitoring
|
Monitoring of power supply model and status
Power supply failure alarming
|
Fan monitoring
|
Fan speed adjustment: 3 levels
Fan failure alarming
|
Temperature monitoring
|
Temperature alarming
|
ESD
|
ESD contact discharge/air discharge: 6 kV/8 kV
ESD immunity contact discharge/air discharge: 8 kV/15 kV
|
Surge protection
|
MGMT port: 4 kV
Service port: 4 kV
Power port: common mode 6 kV, differential mode 6 kV
|
Conformal coating
|
Conformal coating supported (key components only)
|
Certifications and Regulatory Compliance
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Safety regulation
|
IEC 62368-1
|
EMC regulation
|
EN 300386, EN 55032 Class A, EN 55035,
EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
|
Software Specifications
Software Specifications
|
RG-CS86-24MG4VS-UP
|
RG-CS86-12XMG4VS-UP
|
RG-CS86-24XMG4XS4VS-UPD
|
RG-CS86-48MG4VS2QXS-UPD
|
Ethernet switching
|
Jumbo frame (maximum length: 9216 bytes)
|
IEEE 802.1Q (supporting 4K VLANs)
|
Voice VLAN
|
Super VLAN, Private VLAN
|
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN
|
GVRP
|
Basic QinQ
Flexible QinQ
|
STP, RSTP, and MSTP
|
ERPS (G.8032)
|
LLDP/LLDP-MED
|
LACP (IEEE 802.3ad)
|
IP service
|
ARP
|
DHCP client, DHCP relay, and DHCP server
|
DHCP snooping
|
DNS
|
DHCPv6 client and DHCPv6 relay
|
DHCPv6 snooping
|
Neighbor Discovery (ND) and ND snooping
|
IP Routing
|
Static routing
|
RIP and RIPng
|
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6
|
BGP4 and BGP4+
|
IPv4 and IPv6 PBR
|
ECMP
|
Multicast
|
IGMP v1/v2/v3, and IGMP proxy
|
IGMP v1/v2/v3 snooping
|
PIM-DM, PIM-SM, and PIM-SSM
|
MSDP
|
MLD v1/v2
|
MLD snooping v1/v2
|
PIM-SMv6 and PIM-SSM v6
|
ACL and QoS
|
Standard IP ACLs
Extended IP ACLs
Extended MAC ACLs
Time-based ACLs
Expert-level ACLs
ACL80
IPv6 ACL
|
Port traffic rate limiting
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
|
Congestion avoidance: tail drop, RED, and WRED
|
802.1p/DSCP/ToS traffic classification
Eight priority queues per port
|
Security
|
Multiple AAA modes
|
RADIUS and TACAS+
|
Port-based and MAC-based 802.1x authentication
|
Web authentication
|
HTTPS
|
SSHv1, SSHv2
|
Global IP-MAC binding
|
IP source guard
|
SAVI
|
CPP and NFPP
|
Strict and loose RPF
uRPF ignoring default routes
|
Reliability
|
REUP, RLDP, DLDP
|
IPv4 VRRP v2/v3 and IPv6 VRRP
|
BFD
|
GR for RIP, OSPF, BGP
|
1+1 power redundancy
|
Hot swapping of power and fan modules
|
Device virtualization
|
Virtual Switching Unit (VSU)
|
NMS and maintenance
|
SPAN, RSPAN, and ERSPAN
|
sFLOW
|
NTP and SNTP
|
FTP and TFTP
|
SNMP v1/v2/v3
|
RMON (1, 2, 3, 9)
|
NETCONF
|
CWMP (TR-069) standard protocol
|
gRPC
|
Cloud and SON
|
PoE
|
IEEE 802.3af, 802.3at and 802.3bt
Uninterruptible power supply upon hot start
Port priority
|
|